您好,登錄后才能下訂單哦!
這期內容當中小編將會給大家帶來有關為什么MySQL 5.7主庫崩潰切備庫,文章內容豐富且以專業的角度為大家分析和敘述,閱讀完這篇文章希望大家可以有所收獲。
場景:
MySQL主庫無故宕機:判斷是IO問題導致。
The manual page at http://dev.mysql.com/doc/mysql/en/crashing.html contains
information that should help you find out what is causing the crash.
200118 02:11:39 mysqld_safe Number of processes running now: 0
200118 02:11:39 mysqld_safe mysqld restarted
原來主庫的my.cnf:
# For advice on how to change settings please see
# http://dev.mysql.com/doc/refman/5.7/en/server-configuration-defaults.html
# *** DO NOT EDIT THIS FILE. It's a template which will be copied to the
# *** default location during install, and will be replaced if you
# *** upgrade to a newer version of MySQL.
[mysqld]
# Remove leading # and set to the amount of RAM for the most important data
# cache in MySQL. Start at 70% of total RAM for dedicated server, else 10%.
# innodb_buffer_pool_size = 128M
# Remove leading # to turn on a very important data integrity option: logging
# changes to the binary log between backups.
# log_bin
# These are commonly set, remove the # and set as required.
# basedir = .....
# datadir = .....
# port = .....
# server_id = .....
# socket = .....
basedir=/usr/local/mysql
datadir=/data/bak1
socket=/tmp/mysql.sock
server-id =11224722
default_password_lifetime=0
log-bin=/data/bak1/mysql-bin2
expire_logs_days = 1
max_binlog_size =600M
binlog_format = MIXED
#max_allowed_packet =1*1024*1024*1024
max_allowed_packet =1024M
event_scheduler = 1
transaction-isolation = READ-COMMITTED
max_connections=5000
innodb_buffer_pool_size = 80G
# Remove leading # to set options mainly useful for reporting servers.
# The server defaults are faster for transactions and fast SELECTs.
# Adjust sizes as needed, experiment to find the optimal values.
# join_buffer_size = 128M
# sort_buffer_size = 2M
# read_rnd_buffer_size = 2M
sql_mode=NO_ENGINE_SUBSTITUTION,STRICT_TRANS_TABLES
1.確保所有的relay log全部更新完畢,在每個從庫上執行stop slave io_thread; show processlist;
直到看到Has read all relay log,則表示從庫更新都執行完畢了。
2.登陸所有從庫,查看master.info文件,對比選擇pos最大的作為新的主庫,這里我們選擇192.168.112.10為新的主庫。
3.登陸192.168.112.10,執行stop slave; 并進入數據庫目錄,刪除master.info和relay-log.info文件, 配置my.cnf文件,
開啟log-bin,如果有log-slaves-updates和read-only則要注釋掉,執行reset master。
新主庫的my.cnf:
[mysqld]
#datadir=/var/lib/mysql
#socket=/var/lib/mysql/mysql.sock
datadir=/data/db
socket=/tmp/mysql.sock
server-id =111210
log-bin = /data/db/mysql-bin.log
# binlog_format = MIXED
#relay-log = rep_relay_log1
#relay-log-index = rep_relay_log1
#log-error=/data/bak/mysqld1.err
#skip-slave-start = 1
default_password_lifetime=0
# binlog-ignore-db=mysql
#expire_logs_days =7
max_connections = 2000
# user=mysql
# Disabling symbolic-links is recommended to prevent assorted security risks
#symbolic-links=0
max_allowed_packet =1024M
#master_info_repository=table
#relay_log_info_repository=table
#relay_log_recovery=1
#transaction-isolation = READ-COMMITTED
sql_mode=NO_ENGINE_SUBSTITUTION,STRICT_TRANS_TABLES
[mysqld_safe]
log-error=/var/log/mysqld.log
pid-file=/var/run/mysqld/mysqld.pid
4.SHOW MASTER STATUS; 查詢主庫狀態。
OK。
上述就是小編為大家分享的為什么MySQL 5.7主庫崩潰切備庫了,如果剛好有類似的疑惑,不妨參照上述分析進行理解。如果想知道更多相關知識,歡迎關注億速云行業資訊頻道。
免責聲明:本站發布的內容(圖片、視頻和文字)以原創、轉載和分享為主,文章觀點不代表本網站立場,如果涉及侵權請聯系站長郵箱:is@yisu.com進行舉報,并提供相關證據,一經查實,將立刻刪除涉嫌侵權內容。